INTRODUCTION

Esophageal Stents are used to maintain esophageal lumen patency in esophageal strictures caused by intrinsic and/or extrinsic malignancies and the occlusion of concomitant esophageal fistulas. While data on the efficacy and safety of esophageal stents exist, comprehensive evaluation of adverse events is limited. The aim of this study is to investigate the reported adverse events and device failures associated with esophageal self-expandable metal stents (SEMS) using the FDA's Manufacturer and User Facility Device Experience (MAUDE) database.

METHODS

Post-marketing surveillance data for the esophageal SEMSs were analyzed using the FDA's MAUDE database from January 2014 to December 10, 2023. The outcomes of interest were patient-related adverse events and device failures. Statistical analysis was performed using Microsoft Excel 2010 and SPSS. Pooled numbers and percentages were calculated for each adverse event. Continuous variables underwent analysis using a two-tailed student t test, and significance was set to p ≤ 0.05.

RESULTS

During the study period, 548 MAUDE reports revealed 873 device failures and 186 patient-related adverse events. The most common device issues were stent activation, positioning, or separation problems (4 n = 403; 46.2%), followed by device detachment or migration (n = 109, 12.5%), and material problems (n = 93, 10.7%). Patient complications included dysphagia/odynophagia (10%), perforation, pain, and bleeding (each 7.6%). The most common device failures in over-the-wire (OTW) stents and through-the-scope (TTS) stents were activation, positioning, or separation problems (TTS: n = 183, 52.6% vs OTW: n = 220, 41.9%). Compared to OTW stents, TTS stents had higher migration and breakage (13.5% vs. 11.8%, p = 0.24), and (9.2% vs. 6.7%, p = 0.08) respectively, while OTW stents had more challenges with stent advancement or removal (5.1% vs. 0.3%, p < 0.001 and 4.6% vs 3.4%, p = 0.19, respectively) and material problems (14.7% vs. 4.6%, p < 0.001). Activation, positioning, and separation problems were the most frequent device failures in fully covered (FC) and partially covered (PC) stents (FC: n = 62, 32.8%, PC: n = 168, 43.5%). FC stents had higher migration rates (20.6% vs 9.8%, p < 0.001), while PC stents exhibited more material problems (17.4% vs. 5.8%, p < 0.001) and difficulties with advancing the stents (6.7% vs. 0%, p < 0.001).

CONCLUSION

Our examination showed a prevalence of reported device complications associated with stent activation, positioning, and separation problems. Dysphagia or odynophagia emerged as the most frequently reported patient complication. Furthermore, our analysis, provides insights into TTS vs. OTW and FC vs. PC esophageal SEMSs, enabling endoscopists and manufacturers to better understand adverse events and potentially optimize device design for future iterations.

Для цитирования: Jaber Fouad, Alsakarneh Saqr, Alsharaeh Tala, Salahat Ahmed-Jordan, Jaber Mohammad, Mohamed Islam, Gangwani Manesh Kumar, Aldiabat Mohammad, Kilani Yassine, Ahmed Mohamed, Madi Mahmoud, Numan Laith, Bazarbashi Ahmad Najdat. A Comprehensive Analysis of Reported Adverse Events and Device Failures Associated with Esophageal Self-Expandable Metal Stents: An FDA MAUDE Database Study.. Digestive diseases and sciences. 2024. DOI: 10.1007/s10620-024-08483-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.