OBJECTIVES

Describe the result of patent ductus arteriosus (PDA) occlusion using the Amplatz Canine Duct Occluder (ACDO) in 40 dogs. ANIMALS, MATERIAL AND

METHODS

Records of the first 41 dogs at Texas A&M University in which ductal occlusion with an ACDO was attempted were reviewed.

RESULTS

Appropriate device release was achieved in 40 of 41 dogs. Post-release angiography in 39 dogs documented complete occlusion in 27 dogs, trivial residual flow in 7, mild residual flow in 1 and moderate residual flow in 4; angiography was not recorded in one dog. The following day transthoracic color Doppler echocardiography documented complete occlusion in all 40 dogs. One dog required a larger device than could be deployed through the largest sheath accommodated by the femoral artery and the PDA was subsequently closed by surgical ligation.

CONCLUSIONS

Ductal occlusion using an ACDO has a high rate of initial and 24-h complete occlusion. Ductal occlusion using an ACDO is a safe and efficacious therapy for PDA in dogs. This report confirms the positive clinical outcome of the original report in a large cohort of dogs.

Для цитирования: Gordon Sonya G, Saunders Ashley B, Achen Sarah E, Roland Risa M, Drourr Lori T, Hariu Crystal, Miller Matthew W. Transarterial ductal occlusion using the Amplatz Canine Duct Occluder in 40 dogs.. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology. 2010. DOI: 10.1016/j.jvc.2010.04.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.