DOI 10.2147/opth.s381874

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2022

Accuracy and Correlation of the Kinect-Based Semi-Automatic Scoring Method for Measuring Anomalous Head Posture as Compared to the CROM® Device.

Yamamoto Mana, Yagasaki Teiji, Ichikawa Sho, Nakamura Takuto, Konishi Yuumi, Yokoyama Yoshimi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the reliability of the Kinect-based semi-automatic scoring method (KSSM) using Kinect for Windows v2 for head posture compared to the cervical range-of-motion (CROM) device.

METHODS AND ANALYSIS: Head positions between -40° and +40° of chin up/down (X), head turn (Y), and lateral tilt (Z) were measured in 10° increments in healthy volunteers. Their head positions were simultaneously measured using the KSSM and CROM. The following four points were analyzed: the success rate of the KSSM, the correlation between the two methods, the comparison of results by 95% limits of agreement (LA), and proportional error at 95% LA.

RESULTS

The measurability of the KSSM for all positions within ±30° of the X, Y, and Z axes was 100%. The correlations for both methods were 0.979 (95% CI: 0.967-0.987), 0.985 (0.976-0.991), and 0.988 (0.981-0.993) for the X-, Y-, and Z-axes, respectively. The simple linear regression analysis equations for 95% LA were Y=-0.024X-0.452 for X axes, Y=0.024X-0.363 for Y axes, and Y=-0.045X+0.217 for Z axes (95% confidence interval for each axis: -0.055-0.007, -0.006-0.050, and -0.071-0.018). However, the proportional biases were small because the predictive values of the differences in head positions from -40° to 40° determined by the equations were within ± 5° for chin up/down and within ± 3° for head tilt.

CONCLUSION

Head posture measurements using the KSSM and CROM were found to be similar when used in clinical settings.

Для цитирования: Yamamoto Mana, Yagasaki Teiji, Ichikawa Sho, Nakamura Takuto, Konishi Yuumi, Yokoyama Yoshimi. Accuracy and Correlation of the Kinect-Based Semi-Automatic Scoring Method for Measuring Anomalous Head Posture as Compared to the CROM® Device.. Clinical ophthalmology (Auckland, N.Z.). 2022. DOI: 10.2147/opth.s381874.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.