MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2016-013877

Медицинская библиотека · BMJ open · 2017

Methods to decrease variability in histological scoring in placentas from a cohort of preterm infants.

Straughen Jennifer K, Misra Dawn P, Ernst Linda M, Charles Adrian K, VanHorn Samantha, Ghosh Samiran, Buhimschi Irina, Buhimschi Catalin, Divine George, Salafia Carolyn M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Reliable semiquantitative assessment of histological placental acute inflammation is problematic, even among experts. Tissue samples in histology slides often show variability in the extent and location of neutrophil infiltrates. We sought to determine whether the variability in pathologists' scoring of neutrophil infiltrates in the placenta could be reduced by the use of 'regions of interest' (ROIs) that break the sample into smaller components.

DESIGN

ROIs were identified within stained H&E slides from a cohort of 56 women. ROIs were scored using a semiquantitative scale (0-4) for the average number of neutrophils by at least two independent raters.

SETTING

Preterm singleton births at Yale New Haven Hospital.

PARTICIPANTS

This study used stained H&E placental slides from a cohort of 56 women with singleton pregnancies who had a clinically indicated amniocentesis within 24 hours of delivery.

PRIMARY AND SECONDARY OUTCOME MEASURES: Interrater agreement was assessed with the intraclass correlation coefficient (ICC) and log-linear regression. Predictive validity was assessed using amniotic fluid protein profile scores (neutrophil defensin-2, neutrophil defensin-1, calgranulin C and calgranulin A).

RESULTS

Excellent agreement by the ICC was found for the average neutrophil scores within a region of interest. Log-linear analyses suggest that even where there is disagreement, responses are positively associated along the diagonal. There was also strong evidence of predictive validity comparing pathologists' scores with amniotic fluid protein profile scores.

CONCLUSIONS

Agreement among observers of semiquantitative neutrophil scoring through the use of digitised ROIs was demonstrated to be feasible with high reliability and validity.

Для цитирования: Straughen Jennifer K, Misra Dawn P, Ernst Linda M, Charles Adrian K, VanHorn Samantha, Ghosh Samiran, Buhimschi Irina, Buhimschi Catalin, Divine George, Salafia Carolyn M. Methods to decrease variability in histological scoring in placentas from a cohort of preterm infants.. BMJ open. 2017. DOI: 10.1136/bmjopen-2016-013877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.