Standardization of Subcutaneous Injection of Prefilled Anticoagulants Through Lean Six Sigma Management: A Before-After Study.

Deng Ying, Huang Shan, Wang Gong Ming, Cai Dan Ping, Zhang Dong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: The aim of this study was to investigate the impact of the Lean Six Sigma management approach on the standardization of nurses' prefilled anticoagulant subcutaneous injection practices, with a focus on improving anticoagulation outcomes, reducing patient complications, and enhancing overall patient satisfaction.

BACKGROUND

The lack of standards for prefilled anticoagulant injection has resulted in a high complication rate, decreased patient satisfaction, and diminished service quality. This study investigated the impact of the Lean Six Sigma management approach on the standardization of nurses' prefilled anticoagulant subcutaneous injection practices.

METHODS

This study compared pre-implementation and post-implementation data from Lean Six Sigma. A baseline investigation was conducted to determine the type and incidence of complications caused by anticoagulant injection. The nurses' injection process was observed and analyzed to determine problems with the injection technology and the reasons for the reduction in injection quality. Solutions were developed to address these root causes, including formulating a standard process for the subcutaneous injection of preperfusion anticoagulant; recording teaching videos; formulating the standard operating procedure (SOP) while refining, quantifying, and optimizing the operation steps as much as possible; and making an injection site rotation card. Comparative assessments were conducted pre-training and post-training, focusing on nurses' knowledge, standardization of operations, duration of procedures, patient complication rates, and satisfaction with nursing care.

RESULT: Post-training, there was a significant increase in nurses' knowledge and standardization of injection procedures. In addition, there was a notable reduction in the duration of the procedure and patient complications and an increase in patient satisfaction ( P <0.01 or P <0.05).

CONCLUSION

Implementing the Lean Six Sigma management approach effectively standardized nursing procedures for prefilled anticoagulant subcutaneous injections, improved anticoagulation outcomes, minimized patient complications, reduced injection time, and elevated the overall quality of clinical nursing and patient satisfaction.

Для цитирования: Deng Ying, Huang Shan, Wang Gong Ming, Cai Dan Ping, Zhang Dong. Standardization of Subcutaneous Injection of Prefilled Anticoagulants Through Lean Six Sigma Management: A Before-After Study.. The Journal of craniofacial surgery. 2025. DOI: 10.1097/scs.0000000000010893.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.