Development of a semi-automated tool to measure fetal abdominal wall thickness during ultrasound at 20 weeks' gestation.
Аннотация
OBJECTIVES
To develop a semi-automated tool for measuring fetal abdominal wall thickness (AWT). To validate the software using images captured by other centers and create a nomogram for fetal AWT between 18 and 20 weeks.
METHODS
A semiautomated tool that measured AWT was developed using images captured at the routine 20-week morphology scan. The software was developed using digital images captured routinely during scans of low-risk women. Inter- and intraobserver reliability was assessed between manual and semi-automated measures. The tool was validated using images acquired from other centers. Linear regression and quadratic polynomials were used to create a nomogram for AWT.
RESULTS
The semi-automated tool was able to measure AWT in all images. Interoperator reliability was 0.90 and 0.97 (P < 0.05) for manual and semi-automated methods, respectively. Measurement agreement varied between three operators from moderate to excellent (0.77, 0.87, 0.92), with overall agreement being good (0.85). The tool could be successfully applied to 89% of images from other centers. A nomogram was generated for AWT measurements of fetuses at 18-20 weeks in normal, low risk mothers.
CONCLUSION
Semi-automated measurement of AWT was feasible using images captured during the routine 20-week scan. This approach had lower inter- and intraobserver variability compared to manual measurement.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.