Point-of-Care Capillary Blood Ketone Measurements and the Prediction of Future Ketoacidosis Risk in Type 1 Diabetes.
Аннотация
OBJECTIVE
Rather than during illness while diabetic ketoacidosis (DKA) is developing, we aimed to determine if levels of routine point-of-care capillary blood ketones could predict future DKA.
RESEARCH DESIGN AND
METHODS
We examined previously collected data from placebo-assigned participants in an adjunct-to-insulin medication trial program that included measurement of fasted capillary blood ketone levels twice per week in a 2-month baseline period. The outcome was 6- to 12-month trial-adjudicated DKA.
RESULTS
DKA events occurred in 12 of 484 participants at a median of 105 (interquartile range 43, 199) days. Maximum ketone levels were higher in patient cases compared with in control patients (0.8 [0.6, 1.2] vs. 0.3 [0.2, 0.7] mmol/L; P = 0.002), with a nonparametric area under the receiver operating characteristic curve of 0.77 (95% CI 0.66-0.88). Ketone levels ≥0.8 mmol/L had a sensitivity of 64%, a specificity of 78%, and positive and negative likelihood ratios of 2.9 and 0.5, respectively.
CONCLUSIONS
This proof of concept that routine capillary ketone surveillance can identify individuals at high risk of future DKA implies a role for future technologies including continuous ketone monitoring.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.