Assessment of a 3D printed simulator of a lateral ventricular puncture in interns' surgical training.

Hong Wenyao, Liu Yuqing, He Bingwei, Huang Shengyue, Chen Zhongyi, Liao Zhengjian, Yi Zongchao, Su Xiaohang, Shi Jiafeng

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: In this study, a simulator for training lateral ventricular puncture (LVP) was developed using three-dimensional (3D) printing technology, and its function of improving the skills of LVP in young interns was evaluated.

METHODS

A virtual 3D craniocerebral simulator of a 51-year-old female patient with hydrocephalus was reconstructed with 3D printing technology. The anatomical and practical validity were assessed by all interns on a 13-item Likert scale. The usefulness of this simulator was evaluated once a week by two neurosurgeons, based on the performance of the interns, using the objective structured assessment of technical skills (OSATS) scale.

RESULTS

The Likert scale showed that all participants agreed with the overall appearance of the simulator. Also, the authenticity of the skull was the best, followed by the lateral ventricles, analog generation system of intraventricular pressure, cerebrum, and the scalp. This simulator could help the participants' learning about the anatomy of the lateral ventricle, effective training, and repeating the steps of LVP. During training, the interns' ratio of success in LVP elevated gradually. At each evaluation stage, all mean performance scores for each measure based on the OSATS scale were higher than the previous.

CONCLUSIONS

The 3D printed simulator for LVP training provided both anatomical and practical validity, and enabled young doctors to master the LVP procedures and skills.

Для цитирования: Hong Wenyao, Liu Yuqing, He Bingwei, Huang Shengyue, Chen Zhongyi, Liao Zhengjian, Yi Zongchao, Su Xiaohang, Shi Jiafeng. Assessment of a 3D printed simulator of a lateral ventricular puncture in interns' surgical training.. British journal of neurosurgery. 2021. DOI: 10.1080/02688697.2021.1922608.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.