Total and viable residual splenic volume measurement after partial splenic embolization by three-dimensional ultrasound.

Hidaka Hisashi, Wang Guoqin, Nakazawa Takahide, Kida Mitsuhiro, Yanagihara Michiko, Fujii Shigeru, Shibuya Akitaka, Koizumi Wasaburo

СтатьяПеревод в очереди

Аннотация

PURPOSE: We prospectively evaluated the validity of total and viable residual splenic volume after partial splenic embolization (PSE) with three-dimensional (3D) ultrasound (US) measurement.

METHODS

Twenty patients with splenomegaly were included. All splenic volumes were measured with transabdominal US using virtual organ computer-aided analysis (VOCAL). The viable residual splenic volume after PSE was estimated by using contrast-enhanced (CE) US with VOCAL. The agreement of the measurements from VOCAL and computed tomography (CT) was confirmed using interclass correlation coefficients (ICCs) and Bland-Altman plots.

RESULTS

Mean volume was 503 ± 250 ml for total spleen and 209 ± 108 ml for viable residual volume. Regarding total volume, there was a high correlation and agreement (ICCs = 0.90) between 3D US and CT volumetry. Regarding viable residual volume, although there was a moderate correlation between 3D CEUS and CT volumetry, mean ICCs of 0.617 indicated poor agreement. With Bland-Altman plots, a narrow 95 % limit of agreement was observed among patients with a total volume under 1000 ml.

CONCLUSION

The total splenic volume could be accurately estimated with 3D US. However, estimation of viable residual splenic volume should be limited in cases with total splenic volume under 1000 ml.

Для цитирования: Hidaka Hisashi, Wang Guoqin, Nakazawa Takahide, Kida Mitsuhiro, Yanagihara Michiko, Fujii Shigeru, Shibuya Akitaka, Koizumi Wasaburo. Total and viable residual splenic volume measurement after partial splenic embolization by three-dimensional ultrasound.. Journal of medical ultrasonics (2001). 2013. DOI: 10.1007/s10396-013-0443-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.