MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijsu.2011.09.006

Медицинская библиотека · International journal of surgery (London, England) · 2011

A systematic review on the effectiveness of slowly-absorbable versus non-absorbable sutures for abdominal fascial closure following laparotomy.

Sajid M S, Parampalli U, Baig M K, McFall M R

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

To systematically analyse the effectiveness of delayed-absorbable (Polydioxanone; PDS) versus non-absorbable (Polypropylene; Prolene, and Nylon) for abdominal fascial closure in patients undergoing laparotomy.

METHODS

Randomised trials evaluating PDS versus Prolene/Nylon for abdominal fascial closure were selected and analysed by using the statistical tool RevMan where summative data was expressed as odds ratio (OR).

RESULTS

Eight randomised trials encompassing 4261 patients undergoing laparotomy closure with either PDS or Prolene/Nylon were retrieved. There was no statistically significant heterogeneity among trials. In the fixed effect model PDS was comparable to Prolene/Nylon in terms of risk of incisional hernia (OR, 1.10; 95% CI, 0.87, 1.37; z = 0.79; p = 0.43), wound dehiscence (OR, 1.04; 95% CI, 0.67, 1.62; z = 0.19; p = 0.85), peri-operative complications (OR, 0.94; 95% CI, 0.66, 1.33; z = 0.37; p = 0.71), suture sinus formation (OR, 0.58; 95% CI, 0.33, 1.04; z = 1.84; p = 0.07) and surgical site infection (OR, 0.98; 95% CI, 0.68, 1.39; z = 0.14; p = 0.89). Subgroup analysis separately comparing Prolene and Nylon with PDS supported same outcome.

CONCLUSION

PDS and Prolene/Nylon are equally effective for the closure of abdominal fascia following laparotomy. Given that there are no significant differences between two suture materials, further studies may be conducted to evaluate their cost-effectiveness and measurement of health-related quality of life instead of analysing their effectiveness in laparotomy closure.

Для цитирования: Sajid M S, Parampalli U, Baig M K, McFall M R. A systematic review on the effectiveness of slowly-absorbable versus non-absorbable sutures for abdominal fascial closure following laparotomy.. International journal of surgery (London, England). 2011. DOI: 10.1016/j.ijsu.2011.09.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.