Fa yi xue za zhi · 2012
[Relationship between PMI and fourier transform infrared spectral changes in muscle of rats after death caused by mechanical asphyxial].
Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Li Shi-ying, Shao Yu, Li Zheng-dong, Liu Ning-guo, Zou Dong-hua, Qin Zhi-qiang, Chen Yi-jiu, Huang Ping
Аннотация
OBJECTIVE: To observe the postmortem degradation process in rat myocardium and skeletal muscle using Fourier transform infrared (FTIR) spectroscopy and to provide a new method for estimating postmortem interval (PMI).
METHODS: Left ventricle and skeletal muscles of rats dying of mechanical asphyxiated were sampled at different PMIs. The changes of different chemical functional group in the myocardium and skeletal muscle samples were measured by FTIR spectroscopy. The different absorbance (A) ratios of peaks were calculated and the curve estimation analysis between absorbance ratios (x) and PMI (y) were performed to establish six mathematical models.
RESULTS: FTIR spectral absorption peak of rat myocardium and skeletal muscle showed three changes: increase, decrease and stable. The cubic model function showed the strongest correlation coefficient. The A1080/A1396 ratio of skeletal muscle showed the strongest correlation coefficient (r = 0.832) with more accurate determination of PMI.
CONCLUSION: FYIR spectroscopy can be potentially used as an effective method for estimating PMI in forensic practice using myocardium and skeletal muscle.
METHODS: Left ventricle and skeletal muscles of rats dying of mechanical asphyxiated were sampled at different PMIs. The changes of different chemical functional group in the myocardium and skeletal muscle samples were measured by FTIR spectroscopy. The different absorbance (A) ratios of peaks were calculated and the curve estimation analysis between absorbance ratios (x) and PMI (y) were performed to establish six mathematical models.
RESULTS: FTIR spectral absorption peak of rat myocardium and skeletal muscle showed three changes: increase, decrease and stable. The cubic model function showed the strongest correlation coefficient. The A1080/A1396 ratio of skeletal muscle showed the strongest correlation coefficient (r = 0.832) with more accurate determination of PMI.
CONCLUSION: FYIR spectroscopy can be potentially used as an effective method for estimating PMI in forensic practice using myocardium and skeletal muscle.