MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archinte.163.4.452

Медицинская библиотека · Archives of internal medicine · 2003

Imaging characteristics of a novel technetium Tc 99m-labeled platelet glycoprotein IIb/IIIa receptor antagonist in patients With acute deep vein thrombosis or a history of deep vein thrombosis.

Bates Shannon M, Lister-James John, Julian Jim A, Taillefer Raymond, Moyer Brian R, Ginsberg Jeffrey S

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The diagnosis of recurrent deep vein thrombosis (DVT) is challenging. Imaging with radiolabeled peptides offers a new approach for detecting acute DVT. Technetium Tc 99m ((99m)Tc)-apcitide binds with high affinity and specificity to the glycoprotein IIb/IIIa receptors expressed on activated platelets and, therefore, (99m)Tc-apcitide scintigraphy should be negative with residual abnormalities caused by old, inactive thrombi and positive with new, active thrombi.

METHODS

In a prospective multicenter study, (99m)Tc-apcitide imaging was performed on 38 patients with a newly diagnosed first DVT (group 1) and 40 patients with previous DVT, symptoms of postthrombotic syndrome, and chronic intraluminal abnormalities on ultrasonography (group 2). Images were interpreted in a blinded fashion by 2 experts and by newly trained nuclear medicine physicians. The sensitivity and specificity of (99m)Tc-apcitide were determined by calculating the proportion of scans in group 1 patients that were read as "positive for acute DVT" and the proportion of scans in group 2 patients that were read as "negative for acute DVT," respectively.

RESULTS

When read by 2 experts, ( 99m)Tc-apcitide had a sensitivity of 92% for both readers and specificities of 82% and 90%. Agreement between the experts was excellent. However, the accuracy and interreader agreement for newly trained nuclear medicine physicians were lower.

CONCLUSIONS

Technetium Tc 99m-apcitide scintigraphy has potential utility in suspected recurrent DVT because it detects most acute thrombi and has few false-positive results in patients with previous DVT. However, the accuracy appears to depend on the training and experience of the interpreters.

Для цитирования: Bates Shannon M, Lister-James John, Julian Jim A, Taillefer Raymond, Moyer Brian R, Ginsberg Jeffrey S. Imaging characteristics of a novel technetium Tc 99m-labeled platelet glycoprotein IIb/IIIa receptor antagonist in patients With acute deep vein thrombosis or a history of deep vein thrombosis.. Archives of internal medicine. 2003. DOI: 10.1001/archinte.163.4.452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.