MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ac504027d

Медицинская библиотека · Analytical chemistry · 2014

Ultrasensitive photoelectrochemical immunoassay for matrix metalloproteinase-2 detection based on CdS:Mn/CdTe cosensitized TiO2 nanotubes and signal amplification of SiO2@Ab2 conjugates.

Fan Gao-Chao, Han Li, Zhu Hua, Zhang Jian-Rong, Zhu Jun-Jie

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

An ultrasensitive photoelectrochemical sandwich immunoassay was developed to detect matrix metalloproteinase-2 (MMP-2, antigen, Ag) based on CdS:Mn/CdTe cosensitized TiO2 nanotubes (TiO2-NTs) and signal amplification of SiO2@Ab2 conjugates. Specifically, the TiO2-NTs electrode was first deposited with CdS:Mn by successive ionic layer adsorption and reaction technique and then further coated with CdTe quantum dots (QDs) via the layer-by-layer method, forming TiO2-NTs/CdS:Mn/CdTe cosensitized structure, which was employed as a matrix to immobilize capture MMP-2 antibodies (Ab1); whereas, SiO2 nanoparticles were coated with signal MMP-2 antibodies (Ab2) to form SiO2@Ab2 conjugates, which were used as signal amplification elements via the specific antibody-antigen immunoreaction between Ag and Ab2. The ultrahigh sensitivity of this immunoassay derived from the two major reasons as below. First, the TiO2-NTs/CdS:Mn/CdTe cosensitized structure could adequately absorb the light energy, dramatically promote electron transfer, and effectively inhibit the electron-hole recombination, resulting in significantly enhanced photocurrent intensity of the sensing electrode. However, in the presence of target Ag, the immobilized SiO2@Ab2 conjugates could evidently increase the steric hindrance of the sensing electrode and effectively depress the electron transfer, leading to obviously decreased photocurrent intensity. Accordingly, the well-designed photoelectrochemical immunoassay exhibited a low detection limit of 3.6 fg/mL and a wide linear range from 10 fg/mL to 500 pg/mL for target Ag detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising platform for the detection of other important biomarkers.

Для цитирования: Fan Gao-Chao, Han Li, Zhu Hua, Zhang Jian-Rong, Zhu Jun-Jie. Ultrasensitive photoelectrochemical immunoassay for matrix metalloproteinase-2 detection based on CdS:Mn/CdTe cosensitized TiO2 nanotubes and signal amplification of SiO2@Ab2 conjugates.. Analytical chemistry. 2014. DOI: 10.1021/ac504027d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.