MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14072345

Медицинская библиотека · Journal of clinical medicine · 2025

Early Experience Using Tantalum-Loaded Nanocomposite Hydrogel Conformable Embolic for Upper Gastrointestinal Bleeding-Open-Sandwich Technique.

Gad Sandra, Du Pisanie Lourens, Mohnasky Michael, Harris Bryan, Villalobos Alexander, Keefe Nicole, Mody Priya, Caddell Andrew, Kokabi Nima

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

To evaluate the efficacy and safety of using tantalum-loaded Obsidio conformable embolic (Ta-OCE) in gastroduodenal artery (GDA) embolization for upper gastrointestinal bleeding (UGIB), employing a novel "open-sandwich" technique.

Methods

An institutional review board (IRB)-approved retrospective analysis was conducted on patients who underwent GDA embolization for UGIB using Ta-OCE between May 2023 and June 2024, using an "open-sandwich" technique. Briefly, the retrograde sources of flow, namely the right gastroepiploic artery (RGEA), was commonly embolized with a single, usually detachable, coil at its proximal aspect. Beginning within the proximal RGEA adjacent to the coil and distal to the site of extravasation and/or an endoscopically placed clip, Ta-OCE was then instilled in a continuous fashion to the origin of GDA. Technical success was defined as complete occlusion of the target vessel without immediate procedural complications. Clinical success was assessed as the absence of rebleeding within 4 weeks post-embolization. Adverse events were evaluated using Common Toxicity Criteria for Adverse Events (v.5).

Results

Overall, a total of 10 patients, with a mean age of 67.3 years, underwent Ta-OCE embolization for UGIB. A technical success rate of 100% was achieved with no instances of immediate procedural complications. Clinical success was achieved in eight patients (80%). Re-intervention was required in two patients in whom the proximal GDA and distal GDA/proximal RGEA were not embolized adequately, respectively. A significant change in mean hemoglobin levels was observed 24 h pre- and post-embolization, with a mean increase of 1.47 g/dL.

Conclusions

Despite the small sample size, lack of control group, and retrospective design, the "open-sandwich" technique combining Ta-OCE with a single coil appears to be an effective and safe method of GDA embolization in the setting of UGIB. Larger multicenter studies are needed to further evaluate the feasibility of this technique.

Для цитирования: Gad Sandra, Du Pisanie Lourens, Mohnasky Michael, Harris Bryan, Villalobos Alexander, Keefe Nicole, Mody Priya, Caddell Andrew, Kokabi Nima. Early Experience Using Tantalum-Loaded Nanocomposite Hydrogel Conformable Embolic for Upper Gastrointestinal Bleeding-Open-Sandwich Technique.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14072345.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.