DOI 10.1002/jmri.10225

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2003

Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: preliminary experience.

Planken R Nils, Tordoir Jan H M, Dammers Ruben, de Haan Michiel W, Oei T Khiam, van der Sande Freek M, van Engelshoven Jos M A, Leiner Tim

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the feasibility and accuracy of multiphase contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with dysfunctioning hemodialysis arteriovenous fistulae (AVF), using digital subtraction angiography (DSA) as the standard of reference.

MATERIALS AND

METHODS

Fifteen patients with dysfunctioning AVF (eight radiocephalic and seven graft AVF) underwent CE-MRA. Dysfunction was defined as a flow decline of more than 25% in 1 month measured by dilutional flow measurements. CE-MRA was performed during injection of 35 mL of gadolinium-DTPA. The CE-MRA sequence consisted of a time-resolved series of 10 scans, each lasting approximately 10 seconds. The technical parameters were TR/TE/FA/voxel = 5.4/1.6/40/3.1 mm(3), and a rectangular surface reception coil was used. All patients were scheduled to undergo DSA at which an intervention was carried out when a stenosis >or=50% was seen. Two observers, unaware of each other's findings and the findings at DSA, quantified the number and degree of stenosis in the failing AVF. Image quality for CE-MRA and DSA was scored on a 3-point scale. The diagnostic performance of CE-MRA was analyzed with receiver-operator characteristic (ROC) analysis.

RESULTS

CE-MRA and DSA examinations were performed without side effects in all 15 patients. Image quality was scored significantly better on CE-MRA (observer 1: CE-MRA, 2.0; DSA, 1.3; P =.001; observer 2: CE-MRA, 2.0; DSA, 1.4; P =.002). Interobserver agreement for detection of >or=50% stenosis was 0.81 (95% confidence interval (CI) = 0.71-0.92) for CE-MRA and 0.69 (95% CI = 0.55-0.84) for DSA. ROC analysis revealed a mean area under the curve of 0.78. On the patient level, at the >or=50% threshold, mean sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100% (95% CI = 69%-100%), 10% (95% CI = 0%-78%), 70% (95% CI = 38%-92%), and 100% (95% CI = 50%-100%), respectively. At the >or=75% threshold, mean sensitivity, specificity, PPV, and NPV were 75% (95% CI = 20%-99%), 78% (95% CI = 39%-98%), 55% (95% CI = 12%-96%), and 89% (95% CI = 52%-100%), respectively.

CONCLUSION

CE-MRA is a useful diagnostic tool for detecting stenoses in flow-declined hemodialysis AVF prior to interventional DSA.

Для цитирования: Planken R Nils, Tordoir Jan H M, Dammers Ruben, de Haan Michiel W, Oei T Khiam, van der Sande Freek M, van Engelshoven Jos M A, Leiner Tim. Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: preliminary experience.. Journal of magnetic resonance imaging : JMRI. 2003. DOI: 10.1002/jmri.10225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.