MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2014.03.049

Медицинская библиотека · Journal of chromatography. A · 2014

Preparation of a new sorbent based on boronate affinity monolith and evaluation of its extraction performance for nitrogen-containing pollutants.

Hu Hongyou, Zhang Yu, Zhang Yong, Huang Xiaojia, Yuan Dongxing

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this study, a new boronate affinity sorbent based on poly(4-vinylphenylboronic acid-divinylbenzene) monolith (VPB-DB) was prepared and used as extractive medium of stir cake sorptive extraction (SCSE). The effect of the preparation parameters in the polymerization mixture on extraction performance was investigated thoroughly. The sorbent was characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The determination of 8 sulfonamides in environmental water samples with the combination of SCSE and high performance liquid chromatography tandem mass spectrometry detection was selected as a paradigm for the evaluation of extraction performance of poly(VPB-DB) monolith for nitrogen-containing pollutants. Under the optimal extraction conditions, the limits of detection (S/N=3) and limits of quantification (S/N=10) for the target analytes were 0.0012-0.010 and 0.0040-0.033μg/L, respectively. The method also showed good linearity, repeatability, recoveries and high feasibility. At the same time, aromatic amines, nitrophenols, amide herbicides and sudan dyes were also used to evaluate the extractive performance of the sorbent for nitrogen-containing compounds. Results well indicate that the interaction of boron-nitrogen coordination between sorbent and analytes plays a key role in the extraction of nitrogen-containing compounds.

Для цитирования: Hu Hongyou, Zhang Yu, Zhang Yong, Huang Xiaojia, Yuan Dongxing. Preparation of a new sorbent based on boronate affinity monolith and evaluation of its extraction performance for nitrogen-containing pollutants.. Journal of chromatography. A. 2014. DOI: 10.1016/j.chroma.2014.03.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.