MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsmeasuresciau.1c00061

Медицинская библиотека · ACS measurement science au · 2022

Isobaric 4-Plex Tagging for Absolute Quantitation of Biological Acids in Diabetic Urine Using Capillary LC-MS/MS.

Armbruster Michael R, Grady Scott F, Arnatt Christopher K, Edwards James L

СтатьяПеревод в очереди

Аннотация

Isobaric labeling in mass spectrometry enables multiplexed absolute quantitation and high throughput, while minimizing full scan spectral complexity. Here, we use 4-plex isobaric labeling with a fixed positive charge tag to improve quantitation and throughput for polar carboxylic acid metabolites. The isobaric tag uses an isotope-encoded neutral loss to create mass-dependent reporters spaced 2 Da apart and was validated for both single- and double-tagged analytes. Tags were synthesized in-house using deuterated formaldehyde and methyl iodide in a total of four steps, producing cost-effective multiplexing. No chromatographic deuterium shifts were observed for single- or double-tagged analytes, producing consistent reporter ratios across each peak. Perfluoropentanoic acid was added to the sample to drastically increase retention of double-tagged analytes on a C18 column. Excess tag was scavenged and extracted using hexadecyl chloroformate after reaction completion. This allowed for removal of excess tag that typically causes ion suppression and column overloading. A total of 54 organic acids were investigated, producing an average linearity of 0.993, retention time relative standard deviation (RSD) of 0.58%, and intensity RSD of 12.1%. This method was used for absolute quantitation of acid metabolites comparing control and type 1 diabetic urine. Absolute quantitation of organic acids was achieved by using one isobaric lane for standards, thereby allowing for analysis of six urine samples in two injections. Quantified acids showed good agreement with previous work, and six significant changes were found. Overall, this method demonstrated 4-plex absolute quantitation of acids in a complex biological sample.

Для цитирования: Armbruster Michael R, Grady Scott F, Arnatt Christopher K, Edwards James L. Isobaric 4-Plex Tagging for Absolute Quantitation of Biological Acids in Diabetic Urine Using Capillary LC-MS/MS.. ACS measurement science au. 2022. DOI: 10.1021/acsmeasuresciau.1c00061.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.