Venous flow-through flap reconstruction following severe finger wound infection: case report.

George Pravin, DeJesus Ramon A

Клинический случайСтатьяПеревод в очереди

Аннотация

We report a case of a 22-year-old patient who sustained a box-cutter injury to the index finger on her right hand complicated by severe felon. Extensive tissue debridement left the patient with a defect exposing the underlying flexor tendon. A venous flow-through flap from the right forearm was used to provide coverage, which survived completely without venous congestion. Excellent functional and cosmetic result was achieved with this approach. Because of its similarity in color and non-hair-bearing nature, the venous flow-through flap serves as an excellent approach for volar digital defect coverage in which the underlying flexor tendon is exposed.

Для цитирования: George Pravin, DeJesus Ramon A. Venous flow-through flap reconstruction following severe finger wound infection: case report.. Journal of reconstructive microsurgery. 2009. DOI: 10.1055/s-0029-1215525.