A rapid and sensitive enrichment technique, field enhanced sample injection-dynamic pH junction-sweeping (FESI-DypH-sweeping) was successfully developed for the simultaneous separation and concentration of alkaloids and stereoisomers of Uncariae ramulus cum uncis (UR) by cyclodextrin electrokinetic chromatography (CDEKC) with diode array detection system. The sample was prepared in a low-conductivity (FESI), low-pH (DypH) sample matrix (4 mM phosphate buffer, 3% methanol, pH=3), and the background electrolyte (BGE) consisted of a high-conductivity, high-pH buffer (40 mM phosphate buffer, pH 7.0, 8 mg/mL carboxymethyl-β-cyclodextrin, and 30% methanol). The crucial parameters influencing separation and enrichment efficiency were systematically optimized using single variable method. Under the optimum conditions, the method provided satisfactory resolution for seven alkaloids within 18 minutes, achieving enrichment factors ranging from 25 to 78 folds. The limits of detections (LODs) ranged from 0.04 to 0.12 μg/mL and limits of quantifications (LOQs) ranged from 0.10 and 0.40 μg/mL respectively. Intra-day and inter-day precision, expressed as relative standard deviations, were all below 3.5%.

Для цитирования: Liu Wenping, Yao Yaqi, Wen Jiake, Huang Liping, Chen Sujun, Ogaji Omachi Daniel, Li Jin, Du Kunze, Xu Xianjun, Chang Yanxu. Simultaneous stereoisomeric preconcentration and determination of alkaloids and stereoisomers in Uncariae ramulus cum uncis using field enhanced sample injection and dynamic pH junction sweeping method by cyclodextrin electrokinetic chromatography.. Journal of chromatography. A. 2024. DOI: 10.1016/j.chroma.2024.465597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.