Differences in hyperpolarized (3) He ventilation imaging after 4 years in adults with cystic fibrosis.
Аннотация
PURPOSE: To evaluate cystic fibrosis (CF) subjects over 4 years using (3) He magnetic resonance imaging (MRI), pulmonary function tests, and track hospitalization and physician visits.
MATERIALS AND
METHODS
Five CF adults provided written informed consent to an approved protocol and underwent MRI, spirometry, and plethysmography at baseline, 7 days, and 4 ± 1 years later. (3) He MRI ventilation defect percent (VDP) was generated for all subjects and timepoints.
RESULTS
After 4 years, mean forced expiratory volume in 1 second / forced vital capacity (FEV1 /FVC) was lower (P = 0.01) in all subjects and there were no other pulmonary function test changes. Two CF adults showed significantly elevated (worse) (3) He VDP at baseline and after 4 years they had significantly greater (worsened) VDP (P = 0.02), without a significant FEV1 decline (P = 0.06) but with a greater number of exacerbations (P < 0.05). Baseline VDP strongly correlated with FEV1 (r(2) = 0.98, P = 0.0007) at 4-year follow-up.
CONCLUSION
For two CF subjects, VDP was significantly worse at baseline and worsened over 4 years, which was in agreement with a greater number of hospitalizations and clinic visits. These results are limited by the very small sample size, but the strong VDP correlation with longitudinal changes in FEV1 generates the hypothesis that abnormal VDP may temporally precede FEV1 decline in CF subjects; this must be tested in a larger CF study.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.