Glomerular filtration rate measured by (99m) Tc-DTPA renal dynamic imaging is significantly lower than that estimated by the CKD-EPI equation in horseshoe kidney patients.

Qi Yan, Hu Panpan, Xie Yuansheng, Wei Kai, Jin Meiling, Ma Guangyu, Li Qinggang, Xu Baixuan, Chen Xiangmei

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: Gate's glomerular filtration rate (gGFR) measured by (99m) Tc-DTPA renal dynamic imaging and estimated GFR (eGFR) estimated by the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation are two indexes used to evaluate renal function. However, little is known about whether gGFR can be used to accurately assess renal function in horseshoe kidney (HSK) patients with renal fusion anomalies.

METHODS

Nineteen HSK patients (HSK group) diagnosed by renal imaging and 38 CKD patients with "normal kidney shape" (non-HSK group) matched to the HSK patients in terms of gender, age and biochemical indicators at Chinese PLA General Hospital were enrolled in this study. Gender, age, serum total protein (TP), albumin (ALB), blood urea nitrogen (BUN), serum creatinine (Scr), gGFR and eGFR were recorded and analyzed using χ(2) test, t-test, and Wilcoxon test which was presented as median(IQR).

RESULTS

(1) There were no significant differences in gender, age, TP, ALB, BUN, Scr, or eGFR between these two groups. (2) In HSK patients, the renogram showed abnormal renal axis with the lower poles orientated medially. The timed uptake curve showed that the isotope excretion in the HSK group was slower than that in the non-HSK group. (3) For all HSK patients, gGFR was significantly lower than eGFR (range -12.52 mL/min per 1.73m(2) to -93.18 mL/min per 1.73m(2) ). There was no significant difference in eGFR between the HSK [96.42 (36.02) mL/min per 1.73 m(2) ] and non-HSK groups [94.46 (33.00) mL/min per 1.73 m(2) ]. The gGFR of the HSK group [41.18 (16.60) mL/min per 1.73m(2) ] was much lower than that of the non-HSK group [86.42(26.40) mL/min per 1.73m(2) , P < 0.001] and the eGFR of the HSK group (P < 0.001). The gGFR and eGFR of the non-HSK group were not significantly different.

CONCLUSION

gGFR measured by (99m) Tc-DTPA renal dynamic imaging is significantly lower than eGFR estimated by the CKD-EPI equation, which indicates that isotope renogram cannot accurately evaluate the GFR of HSK patients.

Для цитирования: Qi Yan, Hu Panpan, Xie Yuansheng, Wei Kai, Jin Meiling, Ma Guangyu, Li Qinggang, Xu Baixuan, Chen Xiangmei. Glomerular filtration rate measured by (99m) Tc-DTPA renal dynamic imaging is significantly lower than that estimated by the CKD-EPI equation in horseshoe kidney patients.. Nephrology (Carlton, Vic.). 2016. DOI: 10.1111/nep.12663.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.