m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2021

Efficacy and safety of a magnesium stearate paclitaxel coated balloon catheter in the porcine coronary model.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bettink Stephanie, Löchel Melanie, Peters Daniel, Haider Wolfram, Speck Ulrich, Scheller Bruno

Аннотация

BACKGROUND: Local administration of growth-inhibiting substances such as paclitaxel or sirolimus could reduce the risk of restenosis. In the drug coated balloon (DCB) technology the coating and the applied dose seem to play a major role. The aim of the present preclinical studies was to investigate the efficacy and safety of a specific DCB with paclitaxel as active ingredient and magnesium stearate as excipient.

METHODS: Evaluation of the coating, drug release and transfer was done ex vivo and in vivo on peripheral arteries. A porcine coronary stent model was chosen to provoke intimal thickening. Conventional uncoated balloons were compared with paclitaxel urea and paclitaxel magnesium stearate coated balloons. QCA and histomorphometry was performed on treated vessels. Three areas of the heart were histologically examined for pathological changes.

RESULTS: QCA and histomorphometry revealed no differences in baseline data between treatment groups. All DCB groups showed a significant reduction of angiographic and histologic parameters describing neointimal formation 4 weeks after treatment (e.g. mean angiographic late lumen loss all coated 0.31 ± 0.18 mm versus 0.91 ± 0.37 mm in the uncoated balloon group). There were no device-related animal deaths or clinical abnormalities. In spite of very slight-to-slight microscopic findings limited to small arterial vessels in downstream tissue there was no change in left ventricular ejection fraction or angiographic presentation of small side branches of treated arteries.

CONCLUSION: Paclitaxel DCB using stearate as excipient show a high efficacy in reducing neointima formation after experimental coronary intervention. No evidence of myocardial damage resulting from distal embolization was found.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты