Journal of clinical ultrasound : JCU · 2019
Doppler ultrasonography criteria of superior mesenteric artery stenosis.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Biri Suzan, Biri İsmail, Gultekin Yucel, Yurdakul Mehmet, Ozdemir Mustafa, Tola Muharrem
Аннотация
PURPOSE: The techniques mostly used for the diagnosis of superior mesenteric artery (SMA) stenosis are computed tomography angiography (CTA), and magnetic resonance angiography. We aimed to evaluate color-coded Doppler Ultrasonography (CDUS) for the detection of SMA stenoses and to determine Doppler criteria.
METHODS: We identified retrospectively 65 patients with CTA images of SMA stenosis and examined them with CDUS for the Doppler measurement of SMA peak systolic flow velocity (PSV), end-diastolic velocity (EDV), and mesenterico-aortic ratio (MAR). Results were analyzed with receiver-operating characteristic curve analysis.
RESULTS: The optimal threshold values for determining 50%-69% SMA stenoses were PSV >280 cm/s, EDV >45 cm/s, and MAR >3.6. For identifying 70%-99% SMA stenoses, they were PSV >395 cm/s, EDV >74 cm/s, and MAR >3.6.
CONCLUSION: CDUS is a convenient method with high accuracy for identifying SMA stenosis. PSV yielded better results than EDV and MAR.
METHODS: We identified retrospectively 65 patients with CTA images of SMA stenosis and examined them with CDUS for the Doppler measurement of SMA peak systolic flow velocity (PSV), end-diastolic velocity (EDV), and mesenterico-aortic ratio (MAR). Results were analyzed with receiver-operating characteristic curve analysis.
RESULTS: The optimal threshold values for determining 50%-69% SMA stenoses were PSV >280 cm/s, EDV >45 cm/s, and MAR >3.6. For identifying 70%-99% SMA stenoses, they were PSV >395 cm/s, EDV >74 cm/s, and MAR >3.6.
CONCLUSION: CDUS is a convenient method with high accuracy for identifying SMA stenosis. PSV yielded better results than EDV and MAR.