MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2010.06.076

Медицинская библиотека · The Annals of thoracic surgery · 2010

Midterm results after endovascular treatment of acute, complicated type B aortic dissection.

Ehrlich Marek P, Dumfarth Julia, Schoder Maria, Gottardi Roman, Holfeld Johannes, Juraszek Andrzej, Dziodzio Tomasz, Funovics Martin, Loewe Christian, Grimm Michael, Sodeck Gottfried, Czerny Martin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to assess the efficacy and midterm results of endovascular treatment of acute, complicated type B aortic dissection.

METHODS

Between January 2001 and February 2010, 32 patients (7 women, 25 men) with acute, complicated type B aortic dissection (mean age, 56 years; range, 35 to 83 years), defined as either aortic rupture, malperfusion, intractable pain, or uncontrolled hypertension, underwent endovascular stent graft placement with either the Gore Excluder/TAG device (n = 11), Medtronic Talent/Valiant device (n = 16), Bolton Relay (n = 2), or a combination of these stents (n = 3). Follow-up was 94% complete and averaged 26 ± 23 months.

RESULTS

Technical feasibility and success with deployment proximal to the entry tear was 87%, requiring partial or total coverage of the left subclavian artery (LSA) in 9 patients (28%). Hospital mortality was 12% ± 11% (95% confidence limit) with 2 late deaths (17 and 98 months after implant). Causes of hospital death included rupture in 2, retrograde type A dissection in 1, and multiorgan failure in 1 patient. Three patients (11%) experienced new neurologic complications (2 paraparesis and 1 hemiparesis). Six patients with malperfusion required branch vessel stenting. Furthermore, 2 had an early type Ia endoleak. Actuarial survival at 1 and 5 years was 81% and 76%, respectively. Freedom from treatment failure at 1 and 5 years (including reintervention, aortic rupture, device-related complication, and aortic related death) was 78% and 61%, respectively.

CONCLUSIONS

Endovascular stent-graft placement in acute, complicated type B aortic dissection proves to be a promising alternative therapeutic treatment modality in this relatively difficult patient cohort. Refinements, especially in stent design and application, may further improve the prognosis of patients in this life-threatening situation.

Для цитирования: Ehrlich Marek P, Dumfarth Julia, Schoder Maria, Gottardi Roman, Holfeld Johannes, Juraszek Andrzej, Dziodzio Tomasz, Funovics Martin, Loewe Christian, Grimm Michael, Sodeck Gottfried, Czerny Martin. Midterm results after endovascular treatment of acute, complicated type B aortic dissection.. The Annals of thoracic surgery. 2010. DOI: 10.1016/j.athoracsur.2010.06.076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.