m+Medelevator.RU
← Поиск публикаций
Journal of advanced research · 2025

Supra-Carbon dots for methyl-paraoxon detection using a new controllable IFE-based method.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Luo Mai, Cai Jihai, Pu Sijia, Wang Ting, Wu Sijia, Wang Mengwei, Wang Shuangpeng, Qu Songnan, Zou Liang, Li Peng, Wei Jinchao

Аннотация

INTRODUCTION: Pesticide residues pose a significant threat to human health. Inner filter effect (IFE) stands out for its ability to enable the rapid and cost-effective establishment of fluorescent detection systems. Nevertheless, the practical implementation is often hindered by issues such as low spectral overlap and interference from impurities, which can compromise its effectiveness.

OBJECTIVES: To develop novel AIEE-type CDs and apply them to improve the efficiency of IFE-based strategies. With the aid of AIEE-type CDs, we aim to develop a multi-channel detection platform that provides more reliable fluorescent probes for real samples and imaging applications.

METHODS: Preparation of N, S-CDs was achieved using a novel combination of sources. The activation mechanism of Supra-CDs' AIEE characteristics was verified. In the methodological experiments, detection performance of Supra-CDs was tested to confirm their improvement in the IFE-based strategy, practical applicability for real sample detection, and imaging capability.

RESULTS: In this work, p-PA and thiourea were used for the first time to prepare N, S-CDs. After adding water, the fluorescence intensity of Supra-CDs increased by nearly 360 % compared to N, S-CDs. Spectral overlap rates of the target and probe in the controllable IFE-based system improved from 1.80 % to 33.11 %, indicating superior analytical performance in aqueous solutions compared to ethanol. The fluorescent method exhibited a linear range of 0.5-100 μM, with a detection limit of 0.5 μM. Furthermore, a smartphone-based system has been proposed for the colorimetric analysis of methyl paraoxon, offering a more convenient and efficient alternative. Additionally, Supra-CD demonstrated exceptional capabilities in cell imaging, specifically targeting intracellular lipids within HepG2 cells.

CONCLUSION: This study unveils a new type of Supra-CDs that exhibit AIEE property. It also introduces a creative fluorescent sensor with tunable IFE. In summary, this research delivers important insights into AIEE-type Supra-CDs and affirms their potential to inspire broader applications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты