MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3113/fai.2007.1074

Медицинская библиотека · Foot & ankle international · 2007

Biomechanical testing of epitenon suture strength in Achilles tendon repairs.

Shepard Michelle E, Lindsey Derek P, Chou Loretta B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Recent evidence that early, active mobilization protocols after Achilles tendon repairs increase recovery speed and strength make operative repair strength critical to positive outcomes after Achilles tendon ruptures. While previous research has focused on core (tendon proper) repair techniques, no previous literature has reported testing of core repairs augmented with epitenon sutures, which have been shown to increase the strength of repairs of flexor tendons of the hand.

METHODS

Five matched pairs of fresh frozen human Achilles tendons were tested with and without the addition of an epitenon suture to the core repair suture. All specimens were repaired using a No. 2 Ethibond Krakow locking loop core suture. The epitenon suture was added to one tendon randomly chosen from each pair, using a 4-0 nylon suture. All specimens were mounted on an MTS testing machine (MTS Systems Corp., Eden Prairie, MN) and loaded to failure, which was defined as a 1-cm gap formation.

RESULTS

The addition of epitenon sutures significantly increased the force necessary to produce a 2-mm gap as compared to core sutures alone by 74%, and it increased the average load to failure by 119%. Also, initial tendon stiffness was 173% greater in tendons reinforced with epitenon sutures.

CONCLUSIONS

This study demonstrates that greater resistance to gap formation, approximation of tissue ends, and tensile strength were achieved by the addition of an epitenon suture. Clinical relevance may improve healing by decreased gap formation at the repair site and a lower risk of adhesion formation.

Для цитирования: Shepard Michelle E, Lindsey Derek P, Chou Loretta B. Biomechanical testing of epitenon suture strength in Achilles tendon repairs.. Foot & ankle international. 2007. DOI: 10.3113/fai.2007.1074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.