The International journal of oral & maxillofacial implants · 2013
Retrospective analysis of prosthetic complications of implant-supported fixed partial dentures after an observation period of 5 to 10 years.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Vanlıoğlu Burçin, Özkan Yaşar, Kulak-Özkan Yasemin
Аннотация
PURPOSE: The purpose of this study was to evaluate the incidence of the most common technical problems with implant-supported fixed partial dentures (FPDs) and to assess the survival and success rates (event-free survival) after 5 to 10 years of function.
MATERIALS AND METHODS: All of the implants evaluated in this study were from a single manufacturer (Institut Straumann). Follow-up examinations were scheduled 1 week after suprastructure placement, 6 months later, and annually thereafter. Prosthesis-based data on survival/failure rates and technical complications were analyzed.
RESULTS: In 95 partially edentulous patients, 231 Straumann implants were placed and restored with 177 implant-supported prostheses (125 single crowns, 18 splinted crowns on two adjacent implants, and 34 three-unit FPDs). One hundred thirty one solid abutments and 100 synOcta abutments were inserted. The survival rate of prostheses supported by implants was 97.7%. The prosthetic success rate (event-free survival) was 96.05%. After an observation period of 5 years, the cumulative incidence of screw loosening was 0%. Fracture of the veneering porcelain occurred in 3.95% of all restorations. Fractures of the superstructure framework were not observed. The overall incidence of complications after 5 years was highest for splinted crowns, which showed the lowest success rate (94.4%), followed by three-unit FPDs (96%) and single crowns (98.4%).
CONCLUSIONS: Single-unit restorations or short-span FPDs supported by both synOcta and solid abutments on Straumann implants showed low rates of technical complications, the most common being fracture of the veneering porcelain.
MATERIALS AND METHODS: All of the implants evaluated in this study were from a single manufacturer (Institut Straumann). Follow-up examinations were scheduled 1 week after suprastructure placement, 6 months later, and annually thereafter. Prosthesis-based data on survival/failure rates and technical complications were analyzed.
RESULTS: In 95 partially edentulous patients, 231 Straumann implants were placed and restored with 177 implant-supported prostheses (125 single crowns, 18 splinted crowns on two adjacent implants, and 34 three-unit FPDs). One hundred thirty one solid abutments and 100 synOcta abutments were inserted. The survival rate of prostheses supported by implants was 97.7%. The prosthetic success rate (event-free survival) was 96.05%. After an observation period of 5 years, the cumulative incidence of screw loosening was 0%. Fracture of the veneering porcelain occurred in 3.95% of all restorations. Fractures of the superstructure framework were not observed. The overall incidence of complications after 5 years was highest for splinted crowns, which showed the lowest success rate (94.4%), followed by three-unit FPDs (96%) and single crowns (98.4%).
CONCLUSIONS: Single-unit restorations or short-span FPDs supported by both synOcta and solid abutments on Straumann implants showed low rates of technical complications, the most common being fracture of the veneering porcelain.