Zhang J, Qiu R

Аннотация

OBJECTIVES: To evaluate the efficacy of Nd:YAG laser photocoagulation with that of liquid paraffin plus antiseptic cream in the management of recurrent epistaxis.

DESIGN: Prospective clinical study. Eighty consecutive patients with histories of recurrent epistaxis were randomly assigned to receive treatment in an outpatient setting consisting of either a combination of liquid paraffin plus antiseptic cream (group 1) or Nd:YAG laser photocoagulation (group 2).

SETTING: University-affiliated teaching hospital.

PARTICIPANTS: Eighty consecutive patients who suffered from recurrent anterior epistaxis presented to the Otolaryngology Department at the Eye and ENT Hospital, Fudan University between February 2011 and June 2011.

MAIN OUTCOME MEASURES: The following outcome measures were assessed: bleeding intensity, bleeding frequency 4 and 12 weeks after treatment (0 = no bleeding, 1 = reduced bleeding, 2 = the same, 3 = worse), participant's perception of discomfort during the management (grade 0-10, where 10 is the worst pain) and complications.

RESULTS: At 12 weeks, 85% of laser patients versus 40% of control patients had no reported bleeding. The outcome score at 4 weeks after treatment showed no significant difference between the two groups (P = 0.130, P > 0.05); however, the outcome score at 12 weeks after treatment showed a significant difference between the two groups (P = 0.000, P < 0.01). The median and mean ± sd pain levels experienced were 5.0 and 5.2 ± 2.2. Both groups had no complications.

CONCLUSIONS: It can be concluded that Nd:YAG laser photocoagulation is a preferable therapy in the treatment of recurrent epistaxis, especially in terms of long-lasting efficacy. The level of pain associated with the procedure was tolerated. It is a simple, easy, safe and rapid therapy, which can be performed in an office setting.