m+Medelevator.RU
← Поиск публикаций
The Journal of prosthetic dentistry · 2004

The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Eskitascioglu Gurcan, Usumez Aslihan, Sevimay Mujde, Soykan Emel, Unsal Elif

Аннотация

STATEMENT OF PROBLEM: Information about the influence of occlusal loading by location on the stress distribution in an implant-supported fixed partial denture and supporting bone tissue is limited.

PURPOSE: The purpose of this study was to investigate the effect of loading at 1 to 3 different locations on the occlusal surface of a tooth on the stress distributions in an implant-supported mandibular fixed partial denture (FPD) and surrounding bone, using 3-dimensional finite element analysis.

MATERIAL AND METHODS: A 3-dimensional finite element model of a mandibular section of bone (Type 2) with missing second premolar and its superstructures were used in this study. A 1-piece 4.1 x 10-mm screw-shape ITI dental implant system (solid implant) was modeled for this study. Cobalt-Chromium (Wiron 99) was used as the crown framework material and porcelain was used for occlusal surface. The implant and its superstructure were simulated in a Pro/Engineer 2000i program. Total loads at 300 N were applied at the following locations: 1) tip of buccal cusp (300 N); 2) tip of buccal cusp (150 N) and distal fossa (150 N); or 3) tip of buccal cusp (100 N), distal fossa (100 N), and mesial fossa (100 N).

RESULTS: The results demonstrated that vertical loading at 1 location resulted in high stress values within the bone and implant. Close stress levels were observed within the bone for loading at 2 locations and 3 locations; the former created the most extreme stresses and the latter the most even stresses within the bone. With loading at 2 or 3 locations, stresses were concentrated on the framework and occlusal surface of the FPD, and low stresses were distributed to the bone.

CONCLUSION: For the loading conditions investigated, the optimal combination of vertical loading was found to be loading at 2 or 3 locations which decreased the stresses within the bone. In this situation, von Mises stresses were concentrated on the framework and occlusal surface of the FPD.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты