MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2010.01.027

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2010

The trans-subclavian retrograde approach for transcatheter aortic valve replacement: single-center experience.

Bruschi Giuseppe, Fratto Pasquale, De Marco Federico, Oreglia Jacopo, Colombo Paola, Botta Luca, Cannata Aldo, Moreo Antonella, De Chiara Benedetta, Lullo Francesca, Paino Roberto, Martinelli Luigi, Klugmann Silvio

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Aortic valve disease is the most common acquired valvular heart disease in adults. With the increasing elderly population, the proportion of patients with symptomatic aortic stenosis who are unsuitable for conventional surgery is increasing. Transcatheter aortic valve implantation has rapidly gained credibility as a valuable alternative to surgery to treat these patients; however, they often have severe iliac-femoral arteriopathy, which renders the transfemoral approach unusable. We report our experience with the trans-subclavian approach for transcatheter aortic valve implantation using the CoreValve (Medtronic CV Luxembourg S.a.r.l.) in 6 patients.

METHODS

In May 2008 to September 2009, 6 patients (mean age of 82 ± 5 years), with symptomatic aortic stenosis and no reasonable surgical option because of excessive risk, were excluded from percutaneous femoral CoreValve implantation because of iliac-femoral arteriopathy. These patients underwent transcatheter aortic valve implantation via the axillary artery. Procedures were performed by a combined team of cardiologists, cardiac surgeons, and anesthetists in the catheterization laboratory. The CoreValve 18F delivery system was introduced via the left subclavian artery in 6 patients, 1 with a patent left internal thoracic to left anterior descending artery graft.

RESULTS

Procedural success was obtained in all patients, and the mean aortic gradient decreased 5 mm Hg or less immediately after valve deployment. One patient required implantation of a permanent pacemaker. One patient required a subclavian covered stent implantation to treat a postimplant artery dissection associated with difficult surgical hemostasis. One patient was discharged in good condition but died of pneumonia 40 days after the procedure. All patients were asymptomatic on discharge, with good mid-term prosthesis performance.

CONCLUSIONS

Transcatheter aortic valve implantation via a surgical subclavian approach seems safe and feasible, offering a new option to treat select, inoperable, and high-risk patients with severe aortic stenosis and peripheral vasculopathy.

Для цитирования: Bruschi Giuseppe, Fratto Pasquale, De Marco Federico, Oreglia Jacopo, Colombo Paola, Botta Luca, Cannata Aldo, Moreo Antonella, De Chiara Benedetta, Lullo Francesca, Paino Roberto, Martinelli Luigi, Klugmann Silvio. The trans-subclavian retrograde approach for transcatheter aortic valve replacement: single-center experience.. The Journal of thoracic and cardiovascular surgery. 2010. DOI: 10.1016/j.jtcvs.2010.01.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.