MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-022-04798-y

Медицинская библиотека · Clinical oral investigations · 2022

Accuracy and safety of in-house surgeon-designed three-dimensional-printed patient-specific implants for wafer-less Le Fort I osteotomy.

Leung Yiu Yan, Leung Jasper Ka Chai, Li Alvin Tsz Choi, Teo Nathan En Zuo, Leung Karen Pui Yan, Au Shun Wai, Li Dion Tik Shun, Su Yu-Xiong

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The design and fabrication of three-dimensional (3D)-printed patient-specific implants (PSIs) for orthognathic surgery are customarily outsourced to commercial companies. We propose a protocol of designing PSIs and surgical guides by orthognathic surgeons-in-charge instead for wafer-less Le Fort I osteotomy. The aim of this prospective study was to evaluate the accuracy and post-operative complications of PSIs that are designed in-house for Le Fort I osteotomy.

MATERIALS AND

METHODS

The post-operative cone beam computer tomography (CBCT) model of the maxilla was superimposed to the virtual surgical planning to compare the discrepancies of pre-determined landmarks, lines, and principal axes between the two models. Twenty-five patients (12 males, 13 females) were included.

RESULTS

The median linear deviations of the post-operative maxilla of the x, y, and z axes were 0.74 mm, 0.75 mm, and 0.72 mm, respectively. The deviations in the principal axes for pitch, yaw, and roll were 1.40°, 0.90°, and 0.60°, respectively. There were no post-operative complications related to the PSIs in the follow-up period.

CONCLUSIONS

The 3D-printed PSIs designed in-house for wafer-less Le Fort I osteotomy are accurate and safe.

CLINICAL RELEVANCE: Its clinical outcomes and accuracy are comparable to commercial PSIs for orthognathic surgery.

TRIAL REGISTRATION: Clinical trial registration number: HKUCTR-2113. Date of registration: 29 July 2016.

Для цитирования: Leung Yiu Yan, Leung Jasper Ka Chai, Li Alvin Tsz Choi, Teo Nathan En Zuo, Leung Karen Pui Yan, Au Shun Wai, Li Dion Tik Shun, Su Yu-Xiong. Accuracy and safety of in-house surgeon-designed three-dimensional-printed patient-specific implants for wafer-less Le Fort I osteotomy.. Clinical oral investigations. 2022. DOI: 10.1007/s00784-022-04798-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.