MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jclinane.2011.08.006

Медицинская библиотека · Journal of clinical anesthesia · 2012

Reliability of assessment of nasal flow rate for nostril selection during nasotracheal intubation.

Lim Hyung-Sun, Kim Deokkyu, Lee Jeongwoo, Son Ji-Seon, Lee Jun-Rae, Ko Seonghoon

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To evaluate the reliability of assessments of nasal flow rate for improved nostril selection for nasotracheal intubation.

DESIGN

Prospective, randomized, double-blinded study.

SETTING

Operating room of a university-affiliated hospital.

PATIENTS: 118 ASA physical status 1 and 2 patients, aged 18-65 years, scheduled for elective maxillofacial and oral surgery requiring nasotracheal intubation.

INTERVENTIONS: Patients were randomized to the left or right nostril groups. Forced vital capacity (FVC) and forced expiratory volume in one second (FEV(1)) through the mouth and each nostril were measured before anesthesia induction.

MEASUREMENTS: The relationship between the rate of airflow through the selected nostril and frequency of epistaxis and navigability of the nasotracheal tube were evaluated.

MAIN

RESULTS

There were no significant differences in the frequency of epistaxis and degree of navigability of the tracheal tube between the left and right nostril groups. In both nostril groups, patients who suffered epistaxis showed significantly less FEV(1) and FEV(1)/FVC values than did patients without epistaxis (P < 0.05). In addition, in both groups patients who passed the tube easily showed significantly higher FEV(1) and FEV(1)/FVC values than did patients who passed the tube with resistance or failed tube passage (P < 0.05).

CONCLUSION

Measurement of nasal flow rate is a useful clinical method for choosing a nostril for nasotracheal intubation.

Для цитирования: Lim Hyung-Sun, Kim Deokkyu, Lee Jeongwoo, Son Ji-Seon, Lee Jun-Rae, Ko Seonghoon. Reliability of assessment of nasal flow rate for nostril selection during nasotracheal intubation.. Journal of clinical anesthesia. 2012. DOI: 10.1016/j.jclinane.2011.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.