MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2019.01.055

Медицинская библиотека · International journal of cardiology · 2019

Diagnostic accuracy of lung ultrasound for identification of elevated left ventricular filling pressure.

Hubert Arnaud, Girerd Nicolas, Le Breton Hervé, Galli Elena, Latar Ichraq, Fournet Maxime, Mabo Philippe, Schnell Frederic, Leclercq Christophe, Donal Erwan

СтатьяПеревод в очереди

Аннотация

AIMS: The current algorithm in transthoracic echocardiography (TTE) proposed in the 2016 ASE/EACVI recommendation for the estimation of left ventricular filling pressure (LVFP) is quite complex and time-consuming. B-lines, in lung ultrasonography (LUS), could constitute an interesting tool for LVFP evaluation in clinical practice, although data regarding their association with invasive haemodynamics are lacking. The purpose of this study was to explore the diagnostic accuracy of B-lines in identifying elevated left ventricular end-diastolic pressure (LVEDP).

METHOD AND

RESULTS

81 adults with significant dyspnoea (NYHA ≥ 2) were prospectively analyzed by LUS in four areas in each hemithorax and a complete TTE within four hours prior to coronary angiography. Twenty-eight patients had elevated LVEDP. Clinical variables yielded a C-index of 79% to identify elevated LVEDP. The number of total B-lines was higher in the elevated LVEDP group (1.0vs17.0, p < 0.0001) and significantly increased the diagnostic accuracy (C-index increase = 10.5%, p = 0.002) and net reclassification index (NRI = 145.4, 113.0-177.9, p < 0.0001) on top of clinical variables.

CONCLUSION

This study demonstrates the substantial diagnostic capacity of B-lines to identify elevated LVEDP, which appears superior to that of classical echocardiographic strategies. This tool should be considered in a multi-parametric approach in patients with heart failure.

Для цитирования: Hubert Arnaud, Girerd Nicolas, Le Breton Hervé, Galli Elena, Latar Ichraq, Fournet Maxime, Mabo Philippe, Schnell Frederic, Leclercq Christophe, Donal Erwan. Diagnostic accuracy of lung ultrasound for identification of elevated left ventricular filling pressure.. International journal of cardiology. 2019. DOI: 10.1016/j.ijcard.2019.01.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.