MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-1759(02)00019-4

Медицинская библиотека · Journal of immunological methods · 2003

Detection of residual donor leucocytes in leucoreduced red blood cell components using a fluorescence microplate assay.

Gilbert Ruth L, Rider Janet R, Turton J Richard, Pamphilon Derwood H

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

In November 1999, universal leucoreduction of blood components was introduced in the UK to minimise the risk of variant Creutzfeldt-Jakob Disease (vCJD) transmission by blood transfusion. The UK specifications for leucodepletion processes state that 99% of leucodepleted components should contain < 5 x 10(6) leucocytes/unit, within 95% confidence limits. However, this leucocyte concentration is below the detection limits of standard haematology analysers. The development of a fluorometric immunoassay to detect the residual donor leucocytes in leucoreduced blood components is described. Monoclonal antibodies to leucocyte-specific cell surface antigens, CD45 and CD15, were adsorbed to the well surface in 96-well microplates. Red blood cell samples containing low numbers of leucocytes were added to the wells and the cells of interest captured by the monoclonal antibodies. Since leucocytes are the only nucleated cells found in significant numbers in blood components they were quantified using PicoGreen, a fluorescent stain specific for dsDNA. In comparison to flow cytometry, the method currently used to detect low numbers of leucocytes, the microplate assay demonstrated excellent sensitivity (1.00) and acceptable specificity (0.81) when standard leucodepleted samples were tested. There was no significant difference between the two methods (p < or = 0.175). In conclusion, the fluorescence microplate assay represents a simple, high throughput alternative to flow cytometry for monitoring leucodepletion compliance in blood banks.

Для цитирования: Gilbert Ruth L, Rider Janet R, Turton J Richard, Pamphilon Derwood H. Detection of residual donor leucocytes in leucoreduced red blood cell components using a fluorescence microplate assay.. Journal of immunological methods. 2003. DOI: 10.1016/s0022-1759(02)00019-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.