MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41433-019-0424-0

Медицинская библиотека · Eye (London, England) · 2019

Myopic traction maculopathy biomarkers on optical coherence tomography angiography-An overlooked mechanism of visual acuity correction in myopic eyes.

Wang Shih-Wen, Hung Kuo-Chi, Tsai Chia-Ying, Chen Muh-Shy, Ho Tzyy-Chang

СтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

Myopic traction maculopathy of the retinoschisis type is a unique entity that has been frequently overlooked in refraction correction in daily practice in myopic eyes. The objective of this study was to describe the imaging characteristics of myopic traction maculopathy (MTM) seen on optical coherence tomography angiography (OCTA) and to detect biomarkers of the associated functional changes.

SUBJECTS/

METHODS

We performed OCTA on eyes with MTM and retinoschisis (RS group; n = 27) and highly myopic eyes without MTM (control group; n = 27). The RS group was further divided into a dome-shaped macula (DSM) group and a non-DSM group. The groups were compared for morphologic and perfusion characteristics.

RESULTS

The RS and control groups had comparable spherical equivalence (p = 0.65), but the RS group had worse best-corrected visual acuity (p < 0.01), larger retinal volumes (p < 0.01), and greater subfoveal choroid capillary vessel density values (p = 0.04). Compared to the non-DSM group, the DSM group had significantly smaller inner retinal volumes (p = 0.05) and significantly larger choroid capillary vessel density values in both the whole macula (p = 0.005) and the fovea (p = 0.03).

CONCLUSIONS

Our high-resolution OCTA morphologic and vascular perfusion data correlated well with functional abnormalities encountered in myopic eyes. Changes in vessel density may elucidate the pathogenesis of MTM and characterize the mechanical stretch forces acting in eyes with MTM.

Для цитирования: Wang Shih-Wen, Hung Kuo-Chi, Tsai Chia-Ying, Chen Muh-Shy, Ho Tzyy-Chang. Myopic traction maculopathy biomarkers on optical coherence tomography angiography-An overlooked mechanism of visual acuity correction in myopic eyes.. Eye (London, England). 2019. DOI: 10.1038/s41433-019-0424-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.