MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arcped.2009.09.011

Медицинская библиотека · Archives de pediatrie : organe officiel de la Societe francaise de pediatrie · 2009

[Very preterm birth: is maternal anesthesia a risk factor for neonatal intubation in the delivery room?].

Burguet A, Pez O, Debaene B, Untersteller M, Bettinger G, Kayemba-Kays S, Thiriez G, Bouthet M-F, Sanyas P, Menget A, Mulin B, Maillet R, Boisselier P, Pierre F, Gouyon J-B

Аннотация на английскомСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To assess the risk of tracheal intubation at birth in very premature neonates related to the type of maternal anesthesia in case of elective cesarean.

POPULATION AND

METHODS

All 219 live-born very premature neonates (28-32 weeks of gestation), delivered after an elective cesarean in the 27 maternity wards of 2 French semi-rural neonatal networks. Eighty-three percent (182/219) were delivered in level III maternity wards in university hospitals.

RESULTS

Of the very preterm neonates, 33.3% (73/219) were intubated in the delivery room, either for respiratory distress syndrome or a low APGAR score. Very preterm neonates delivered after maternal general anesthesia were more often intubated than those delivered after spinal anesthesia (48.7% vs 25.2%; OR: 2.8; 95% CI: 1.8-5.1). The risk of intubation related to maternal general anesthesia remained statistically significant after an adjustment for gestational age, fetal growth retardation, respiratory distress syndrome, type of maternity ward, and a propensity score that took into account maternal sociodemographic characteristics and the causes of very preterm birth (aOR: 3.4; 95% CI: 1.4-8.2). The risk of intubation related to general anesthesia was lower after adjusting for the 5-min APGAR score (aOR: 2.8; 95% CI: 1.0-7.3).

CONCLUSION

Very preterm neonates delivered after cesarean with general anesthesia require tracheal intubation in the delivery room more often than those delivered with spinal anesthesia. This study cannot assess a causal link between anesthesia and the need for neonatal intubation. However, neonatologists have to be aware of the type of maternal anesthesia because it may interfere with the non-invasive ventilation support policy of the very preterm neonate.

Для цитирования: Burguet A, Pez O, Debaene B, Untersteller M, Bettinger G, Kayemba-Kays S, Thiriez G, Bouthet M-F, Sanyas P, Menget A, Mulin B, Maillet R, Boisselier P, Pierre F, Gouyon J-B. [Very preterm birth: is maternal anesthesia a risk factor for neonatal intubation in the delivery room?].. Archives de pediatrie : organe officiel de la Societe francaise de pediatrie. 2009. DOI: 10.1016/j.arcped.2009.09.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.