DOI 10.1007/s12350-021-02713-8
Integration of quantitative absolute myocardial blood flow estimates from dynamic CZT-SPECT improves the detection of coronary artery disease.
Аннотация
BACKGROUND
Balanced ischemia with multi-vessel coronary artery disease (CAD) is difficult to diagnose with semiquantitative single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Dynamic cardiac SPECT provides quantitative estimations of stenosis severity and ischemic burden by assessing myocardial flow reserve (MFR) and myocardial blood flow (MBF). The aim of this study was to evaluate the incremental value of dynamic SPECT in multi-vessel coronary artery disease (CAD).
METHODS
Patients with suspected CAD who underwent dynamic ECG-gated dipyridamole MPI and coronary angiography within 6 months were retrospectively reviewed. The performance of summed stress, rest and difference scores (SSS, SRS, SDS), post-stress and resting MBF (MBFs, MBFr) and MFR were compared at both patient level and vessel level.
RESULTS
In 32 patients with 39 stenotic vessels, 12 had three-vessel disease (38%). Globally increased SSS and impaired MBF values were significantly associated with significant CAD at the patient level, but SDS and MFR were not. Regional increases in SSS and reductions in both MBFs and MBFr were significantly associated with stenotic vessels. The best cutoff value of global MBFs to predict CAD was 3.5 ml·g-1·min-1 (area under the curve, AUC = .84, P = .002). The best cutoff value of regional MBFs to detect significant stenosis was 3.6 ml·g-1·min-1 (AUC = .74, P < .001). However, the best possible cut-off values of MFR were not found. Sex-difference in both global and regional MBFr but MBFs was found, which might result in the non-significance in MFR.
CONCLUSIONS
This study validated a clinically available method to quantify MFR using dynamic CZT-SPECT. This method improved the detectability of multi-vessel CAD, and absolute MBFs was superior to MFR and other semiquantitative MPI parameters.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.