DOI 10.1111/j.0004-8666.2002.00205.x
A retrospective cohort study comparing microwave endometrial ablation with levonorgestrel-releasing intrauterine device in the management of heavy menstrual bleeding.
Аннотация
OBJECTIVE
To compare microwave endometrial ablation (MEA) with a levonorgestrel-releasing intrauterine device (Mirena) in the management of heavy menstrual bleeding.
DESIGN
A retrospective cohort study
SAMPLE: Thirty-nine women were treated with MEA and 23 women with Mirena, in the South East Regional Health Service of South Australia during 1998 to 2001; the mean duration of follow-up was 14.6 months.
MAIN OUTCOME MEASURES: Primary measures included acceptability of the treatment process, effectiveness of the treatment, and satisfaction with outcomes. Secondary measures included side effects, complications and quality of life (using the SF-36).
RESULTS
Acceptability of the treatment process and satisfaction with outcomes was very high for both procedures. Each treatment led to a statistically significant reduction in menstrual bleeding (p < 0.0001) and dysmenorrhoea scores (p < 0.002).
CONCLUSIONS
There were no statistical differences between the two treatments for any of the primary or secondary outcome measures assessed. The treatments seem equally effective in the management of heavy menstrual loss.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.