MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/jpm-2016-0315

Медицинская библиотека · Journal of perinatal medicine · 2017

Three-dimensional ultrasound first trimester fetal volume measurement and its relation to pregnancy outcome.

Torky Haitham A, Moussa Asem A, Ahmad Ali M, Dief Osama, Eldesoouky Manar A, El-Gayed Ahmed S

СтатьяПеревод в очереди

Аннотация

AIM OF WORK: To determine whether fetal volume (FV) measured by three-dimensional (3D) ultrasound was able to detect fetuses at risk of low birth weight (primary outcome) and/or preterm labor (secondary outcome).

METHODS

One hundred pregnant women carrying a singleton living pregnancy who were sure of dates, and had a dating scan, with gestational age between 11 weeks and 13 weeks+6 days coming for routine first trimester nuchal translucency (NT) were examined by both two-dimensional (2D) and 3D ultrasound (Vocal System) for crown-rump length (CRL) and FV then followed up regularly every 4 weeks until 28 weeks then biweekly until 36 weeks then weekly until delivery both clinically and by ultrasound biometry.

FINDINGS: Eighty-seven cases had a normal outcome, while the remaining 13 cases had either preterm labor (four cases) or low-birth weight (nine cases). FV positively correlated with CRL (P=0.026), gestational age in weeks (P=0.002), neonatal body weight in grams (P=0.018) and neonatal body length at birth (P=0.04). A mean FV of 8.3 mm3 was association with neonatal complications (P=0.045). A cut-off point of 9 mm3 for FV was associated with 100% sensitivity for detection of the date of birth, while a cut-off point of 9.15 mm3 for FV was associated 100% sensitivity for detection of neonatal birth weight.

CONCLUSION

3D assessment of FV in the first trimester provides an accurate method for predicting pregnancy outcome namely low birth weight and neonatal complications, however, it is a better positive predictor than a negative one.

Для цитирования: Torky Haitham A, Moussa Asem A, Ahmad Ali M, Dief Osama, Eldesoouky Manar A, El-Gayed Ahmed S. Three-dimensional ultrasound first trimester fetal volume measurement and its relation to pregnancy outcome.. Journal of perinatal medicine. 2017. DOI: 10.1515/jpm-2016-0315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.