MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2011.12.004

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2011

Prediction of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.

Edwin Frank, Kinsley Robin H, Quarshie Alexander, Colsen Peter R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We sought to determine the value of preoperative left ventricular function and cardiopulmonary bypass parameters in the prediction of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.

METHODS

Multivariate logistic regression was performed to identify a predictive model for postrepair left ventricular assist device implantation using the records of 27 patients who underwent direct aortic implantation of anomalous left coronary artery from the pulmonary artery from 1994 to 2011.

RESULTS

Seven patients required left ventricular assist device implantation. Patients in group 1 (n = 20) were successfully weaned from cardiopulmonary bypass. Patients in group 2 (n = 7) required left ventricular assist device as a bridge to recovery. The 2 groups were similar in age, weight, and body surface area. Six of the 7 patients (85.7%) who required left ventricular assist device survived to hospital discharge. Hospital mortality was 3.7%. In the univariate model, fractional shortening, ejection fraction, and aortic crossclamp time were significantly associated with left ventricular assist device implantation (P = .026, .035, .031, respectively). In the multivariate analysis, the aortic crossclamp time was the only significant independent predictor of left ventricular assist device implantation. Aortic crossclamp time and fractional shortening together accounted for 80.9% (P < .001) of the variability in left ventricular assist device implantation and constituted the best predictive model: All patients requiring postrepair left ventricular assist device implantation had a fractional shortening less than 20% and an aortic crossclamp time greater than 56 minutes.

CONCLUSIONS

The fractional shortening and aortic crossclamp time together predict 80.9% of the variability in postrepair left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery. When preoperative left ventricular dysfunction is severe (fractional shortening < 20%), an aortic crossclamp time greater than 56 minutes is associated with a substantial risk of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.

Для цитирования: Edwin Frank, Kinsley Robin H, Quarshie Alexander, Colsen Peter R. Prediction of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.. The Journal of thoracic and cardiovascular surgery. 2011. DOI: 10.1016/j.jtcvs.2011.12.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.