Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
van Veenendaal Mariëtte B, Miedema Martijn, de Jongh Frans H C, van der Lee Johanna H, Frerichs Inez, van Kaam Anton H
Аннотация
OBJECTIVE: To determine the global and regional changes in lung volume during and after closed endotracheal tube (ETT) suction in high-frequency ventilated preterm infants with respiratory distress syndrome (RDS).
DESIGN: Prospective observational clinical study.
SETTING: Neonatal intensive care unit.
PATIENTS: Eleven non-muscle relaxed preterm infants with RDS ventilated with open lung high-frequency ventilation (HFV).
INTERVENTIONS: Closed ETT suction.
MEASUREMENTS AND RESULTS: Changes in global and regional lung volume were measured with electrical impedance tomography. ETT suction resulted in an acute loss of lung volume followed by spontaneous recovery with a median residual loss of 3.3% of the maximum volume loss. The median stabilization time was 8 s. At the regional level, the lung volume changes during and after ETT suction were heterogeneous in nature.
CONCLUSIONS: Closed ETT suction causes an acute, transient and heterogeneous loss of lung volume in premature infants with RDS treated with open lung HFV.
DESIGN: Prospective observational clinical study.
SETTING: Neonatal intensive care unit.
PATIENTS: Eleven non-muscle relaxed preterm infants with RDS ventilated with open lung high-frequency ventilation (HFV).
INTERVENTIONS: Closed ETT suction.
MEASUREMENTS AND RESULTS: Changes in global and regional lung volume were measured with electrical impedance tomography. ETT suction resulted in an acute loss of lung volume followed by spontaneous recovery with a median residual loss of 3.3% of the maximum volume loss. The median stabilization time was 8 s. At the regional level, the lung volume changes during and after ETT suction were heterogeneous in nature.
CONCLUSIONS: Closed ETT suction causes an acute, transient and heterogeneous loss of lung volume in premature infants with RDS treated with open lung HFV.