MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.120.020033

Медицинская библиотека · Journal of the American Heart Association · 2021

Temporal Incidence and Predictors of High-Grade Atrioventricular Block After Transcatheter Aortic Valve Replacement.

El-Sabawi Bassim, Welle Garrett A, Cha Yong-Mei, Espinosa Raúl E, Gulati Rajiv, Sandhu Gurpreet S, Greason Kevin L, Crestanello Juan A, Friedman Paul A, Munger Thomas M, Rihal Charanjit S, Eleid Mackram F

СтатьяПеревод в очереди

Аннотация

Background The temporal incidence of high-grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre- and post-TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post-TAVR). A total of 953 patients were included in this study. HAVB occurred in 153 (16.1%). After exclusion of those with prophylactic PPM placed post-TAVR, the incidence of delayed HAVB was 33/882 (3.7%). Variables independently associated with delayed HAVB included baseline first-degree atrioventricular block or right bundle-branch block, self-expanding valve, and new left bundle-branch block. Forty patients had intraprocedural transient HAVB, including 16 who developed HAVB recurrence and 6 who had PPM implantation without recurrence. PPM was placed for HAVB in 130 (13.6%) (self-expanding valve, 23.7% versus balloon-expandable valve, 11.9%; P<0.001). Eight (0.8%) patients died by 30 days, including 1 unexplained without PPM present. Conclusions Delayed HAVB occurs with higher frequency in patients with baseline first-degree atrioventricular block or right bundle-branch block, new left bundle-branch block, and self-expanding valve. These findings provide insight into optimal monitoring and pacing strategies based on periprocedural ECG findings.

Для цитирования: El-Sabawi Bassim, Welle Garrett A, Cha Yong-Mei, Espinosa Raúl E, Gulati Rajiv, Sandhu Gurpreet S, Greason Kevin L, Crestanello Juan A, Friedman Paul A, Munger Thomas M, Rihal Charanjit S, Eleid Mackram F. Temporal Incidence and Predictors of High-Grade Atrioventricular Block After Transcatheter Aortic Valve Replacement.. Journal of the American Heart Association. 2021. DOI: 10.1161/jaha.120.020033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.