MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/ijn.s591943

Медицинская библиотека · International journal of nanomedicine · 2026

DNA Aptamer-Functionalized Fluorescent Silica Nanoparticles: A Robust Strategy for Specific Detection and Bioimaging of HER2-Overexpressing Breast Cancer.

Tan Juntao, Hu Zixi, Huang Da, Cheng Suqing, Chen Lu, Min Liangliang, Tu Jianhong, Li Zhihua

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Precise detection of HER2-positive breast cancer is vital for targeted therapy. This study integrates HER2-specific DNA aptamers with fluorescent silica nanoparticles (FSNPs) to develop a targeted imaging probe.

METHODS

HER2 aptamer-conjugated FSNPs (HApt-FSNPs) were synthesized and characterized. Specificity was evaluated in HER2-positive/negative cells and tumor sections via flow cytometry and microscopy. Targeting efficacy and biodistribution were assessed in tumor-bearing mice through systemic injection and real-time fluorescence imaging. Photostability and biosafety were systematically examined.

RESULTS

HApt-FSNPs showed uniform size, excellent dispersity, and enhanced photostability. They selectively bound HER2-positive cells and tumor tissues, with binding effectively blocked by free aptamer. In vivo imaging revealed specific accumulation in HER2-positive tumors, peaking at 6 hours post-injection, with minimal off-target signals. The probe demonstrated good biocompatibility in vitro and in vivo.

CONCLUSION

The HApt-FSNP platform enables specific detection and in vivo imaging of HER2-positive breast cancer, highlighting its potential for diagnostic and bioimaging applications.

Для цитирования: Tan Juntao, Hu Zixi, Huang Da, Cheng Suqing, Chen Lu, Min Liangliang, Tu Jianhong, Li Zhihua. DNA Aptamer-Functionalized Fluorescent Silica Nanoparticles: A Robust Strategy for Specific Detection and Bioimaging of HER2-Overexpressing Breast Cancer.. International journal of nanomedicine. 2026. DOI: 10.2147/ijn.s591943.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.