Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system.

Bradley Veronica C, Spano Tyler L, Thompson Cyril V, Ticknor Brian W, Dunlap Daniel R, Metzger Shalina C, Hexel Cole R, Manard Benjamin T

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

An automated microextraction method coupled to an inductively coupled plasma - mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO2F2), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235U/238U and 234U/238U isotope ratios for the UO2F2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of -0.041% and -1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235U/238U isotope ratio of 0.00206(7), a -0.96% relative difference from the reference value of 0.00208(1). The 234U/238U and 236U/238U isotope ratios were 0.000008(1) and 0.000031(4), -5.1% RD and -4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface - including blanks, mass bias, and triplicate extractions - was completed in less than an hour without any sample preparation necessary.

Для цитирования: Bradley Veronica C, Spano Tyler L, Thompson Cyril V, Ticknor Brian W, Dunlap Daniel R, Metzger Shalina C, Hexel Cole R, Manard Benjamin T. Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system.. Analytical methods : advancing methods and applications. 2022. DOI: 10.1039/d2ay01394k.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.