MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjane.2023.07.012

Медицинская библиотека · Brazilian journal of anesthesiology (Elsevier) · 2023

Metoprolol for prevention of bucking at orotracheal extubation: a double-blind, placebo-controlled randomised trial.

de Queiroz Murilo Neves, Mendonça Fabrício Tavares, de Matos Maurício Vargas, Lino Rafael Santos, de Carvalho Luiz Sérgio Fernandes

Рандомизированное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Respiratory responses to extubation can cause serious postoperative complications. Beta-blockers, such as metoprolol, can interfere with the cough pathway. However, whether metoprolol can effectively control respiratory reflexes during extubation remains unclear. The objective of this study is to evaluate the efficacy of intravenous metoprolol in attenuating respiratory responses to tracheal extubation.

METHODS

Randomized, double-blinded, placebo-controlled trial.

SETTING

Tertiary referral center located in Brasília, Brazil. Recruitment: June 2021 to December 2021.

SAMPLE: 222 patients of both sexes with an American Society of Anesthesiologists (ASA) physical status I-III aged 18-80 years. Patients were randomly assigned to receive intravenous metoprolol 5 mg IV or placebo at the end of surgery. The primary outcome was the proportion of patients who developed bucking secondary to endotracheal tube stimulation of the tracheal mucosa during extubation. Secondary outcomes included coughing, bronchospasm, laryngospasm, Mean Blood Pressure (MAP), and Heart Rate (HR) levels.

RESULTS

Two hundred and seven participants were included in the final analysis: 102 in the metoprolol group and 105 in the placebo group. Patients who received metoprolol had a significantly lower risk of bucking (43.1% vs. 64.8%, Relative Risk [RR = 0.66], 95% Confidence Interval [95% CI 0.51-0.87], p = 0.003). In the metoprolol group, 6 (5.9%) patients had moderate/severe coughing compared with 33 (31.4%) in the placebo group (RR = 0.19; 95% CI 0.08-0.43, p < 0.001).

CONCLUSION

Metoprolol reduced the risk of bucking at extubation in patients undergoing general anesthesia compared to placebo.

Для цитирования: de Queiroz Murilo Neves, Mendonça Fabrício Tavares, de Matos Maurício Vargas, Lino Rafael Santos, de Carvalho Luiz Sérgio Fernandes. Metoprolol for prevention of bucking at orotracheal extubation: a double-blind, placebo-controlled randomised trial.. Brazilian journal of anesthesiology (Elsevier). 2023. DOI: 10.1016/j.bjane.2023.07.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.