Therapeutic drug monitoring · 2018
Development of an Abbreviated Mycophenolic Acid Area Under the Time-Concentration Curve for Renal Transplant Patients Under Enteric-Coated Mycophenolate Sodium: A Comparison With Critical Analysis of Available Equations.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
David-Neto Elias, Triboni Ana Heloisa, Ramos Fernanda, Agena Fabiana, Romano Paschoalina
Аннотация
BACKGROUND: Enteric-coated mycophenolate sodium is frequently used in renal transplantation. The pharmacokinetic profile of mycophenolic acid (MPA) shows a broad range of time-to-maximum concentration (Tmax) that limits the use of a single MPA concentration to calculate the area under the time-concentration curve (AUC). For both research and clinical MPA monitoring, measuring a complete AUC is troublesome to the center and patients.
METHODS: We obtained 171 complete MPA-AUC12h (0, 20, 40, 60, 90, 120, 180, 240, 360, 480, 600, and 720 minutes) from 59 adult (54 ± 16 years) patients (29 men and 43 whites) who have been receiving stable doses of tacrolimus/enteric-coated mycophenolate sodium and steroids. We used the 59 curves drawn at 31 ± 4 days after transplantation to develop the abbreviated equations, and the remaining 112 curves drawn at 109 ± 59 days were used to validate them. We used 5 other proposed equations to estimate MPA-AUC (eAUC) (4 with enzyme-multiplied immunoassay technique assay and one with high-performance liquid chromatography [HPLC]) and then used these results to compare with our measured AUC, the bias, and the 10% and 30% accuracy. MPA was measured by ultraperformance liquid chromatography coupled to a tandem mass spectrometry, and AUC was calculated by the trapezoidal rule.
RESULTS: For both MPA-measuring methods, enzyme-multiplied immunoassay technique and ultraperformance liquid chromatography coupled to a tandem mass spectrometry, the Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) equations, and others that measure MPA up to 6 hours after the dose had an acceptable low bias with more results in the 10%-30% range than those using data collected until 4 hours. A highly adequate eAUC is obtained using blood collected at 8 hours.
CONCLUSIONS: This analysis offers blood-sampling alternatives for MPA monitoring depending on the precision needed.
METHODS: We obtained 171 complete MPA-AUC12h (0, 20, 40, 60, 90, 120, 180, 240, 360, 480, 600, and 720 minutes) from 59 adult (54 ± 16 years) patients (29 men and 43 whites) who have been receiving stable doses of tacrolimus/enteric-coated mycophenolate sodium and steroids. We used the 59 curves drawn at 31 ± 4 days after transplantation to develop the abbreviated equations, and the remaining 112 curves drawn at 109 ± 59 days were used to validate them. We used 5 other proposed equations to estimate MPA-AUC (eAUC) (4 with enzyme-multiplied immunoassay technique assay and one with high-performance liquid chromatography [HPLC]) and then used these results to compare with our measured AUC, the bias, and the 10% and 30% accuracy. MPA was measured by ultraperformance liquid chromatography coupled to a tandem mass spectrometry, and AUC was calculated by the trapezoidal rule.
RESULTS: For both MPA-measuring methods, enzyme-multiplied immunoassay technique and ultraperformance liquid chromatography coupled to a tandem mass spectrometry, the Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) equations, and others that measure MPA up to 6 hours after the dose had an acceptable low bias with more results in the 10%-30% range than those using data collected until 4 hours. A highly adequate eAUC is obtained using blood collected at 8 hours.
CONCLUSIONS: This analysis offers blood-sampling alternatives for MPA monitoring depending on the precision needed.