Idioventricular rhythm and shock after a honeybee sting.

Franco-Lugo Desireé, Uribe-Vallarta Denise A, Bernal-Contreras Karen D, Vargas-Abonce Valerie P, Soto-Pérez-De-Celis Enrique, Rivera-Figueroa Jaime, Cuevas-Ramos Daniel, Gómez-Pérez Francisco J, Gómez-Sámano Miguel Á

Клинический случайСтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study was to describe the case of a 19-year-old male presenting with bradycardia and hypotension after a honeybee sting making a review of the literature and pathophysiology of the cardiovascular and electrocardiogram (EKG) changes after a bee sting.

METHODS

The patient's airway was inspected and secured. Electrocardiogram with an idioventricular rhythm at 41' bpm. Oxygen was administered, an intravenous access was established, and the transcutaneous pacemaker leads were placed on the chest of the patient, then published guidelines management was induced.

RESULTS

The EKG showed idioventricular rhythm at a rate of 41 beats/min that resolved to a normal sinus rhythm after treatment.

CONCLUSIONS

A full and prompt cardiovascular evaluation should be performed in all patients presenting to the emergency department after a bee sting, and published guidelines regarding the management of bradycardia and anaphylaxis should be followed to achieve successful outcomes.

Для цитирования: Franco-Lugo Desireé, Uribe-Vallarta Denise A, Bernal-Contreras Karen D, Vargas-Abonce Valerie P, Soto-Pérez-De-Celis Enrique, Rivera-Figueroa Jaime, Cuevas-Ramos Daniel, Gómez-Pérez Francisco J, Gómez-Sámano Miguel Á. Idioventricular rhythm and shock after a honeybee sting.. Archivos de cardiologia de Mexico. 2021. DOI: 10.24875/acm.20000035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.