m+Medelevator.RU
← Поиск публикаций
Journal of cardiac surgery · 2010

Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stern David R, Kazam Jacob, Edwards Pauline, Maybaum Simon, Bello Ricardo A, D'Alessandro David A, Goldstein Daniel J

Аннотация

BACKGROUND: The HeartMate II (HMII) Left Ventricular Assist System (Thoratec Corporation, Pleasanton, CA, USA), an axial continuous-flow left ventricular assist device (LVAD), has been approved for use in bridge-to-transplant patients and is under investigation for destination therapy. To avoid device-related thromboembolic complications, antiplatelet, and anticoagulation therapy are routinely administered. A worrisome frequency of gastrointestinal (GI) bleeding events has been observed.

METHODS: A retrospective review of all 33 patients undergoing long-term LVAD implantation between June 1, 2006 and July 31, 2008 at our institution for any indication was conducted. Anticoagulation consisted of heparin (intravenous or subcutaneous) followed by transition to Coumadin therapy to a target INR of two to three. Antiplatelet therapy consisted of low-dose aspirin and dipyridamole.

RESULTS: Twenty patients received the HMII and 13 patients received other devices. Eight (40%) HMII recipients suffered at least one episode of GI bleeding while no GI bleeding occurred in recipients of other devices (p = 0.012). Of 17 total bleeding episodes, no definitive source could be identified in 11 instances (65%).

CONCLUSIONS: Although definitive source identification remains elusive, we believe that the majority of bleeding arises in the small bowel, possibly due to angiodysplasias, similar to the pathophysiology encountered in patients with aortic stenosis and GI bleeding. As we move toward wider use of the HMII and other axial continuous-flow devices in both bridge-to-transplant patients and for destination therapy, more studies will be necessary to understand the mechanisms of this obscure GI bleeding and develop treatment strategies to minimize its development.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты