DOI 10.1016/j.jcrs.2010.11.042

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Bacterial-sized particle inflow through sutured clear corneal incisions in a laboratory human model.

May William N, Castro-Combs Juan, Kashiwabuchi Renata T, Hertzog Hans, Tattiyakul Woranart, Kahn Yasin A, Hirai Flavio, Gower Emily W, Behrens Ashley

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine the effectiveness of a single radial suture placement in 2 clear corneal incision (CCI) configurations in preventing inflow of bacterial-sized particles.

SETTING

Wilmer Eye Institute, Baltimore, Maryland, USA.

DESIGN

Experimental study.

METHODS

Ten human globes were used. Two 25-gauge needles connected to a saline solution bag and to a digital manometer were inserted through the limbus 120 degrees apart. Four incision-suture combinations were evaluated sequentially in each cornea. All incisions had the same dimensions (2.75 mm width, 3.00 mm length). Two incisions were single plane, and 2 were biplane. One incision from each configuration was left unsutured, and the other was sutured (10-0 nylon). With a preset 10 mm Hg intraocular pressure (IOP), India ink was applied to the incision site and a sudden IOP fluctuation was induced. Inflow was outlined and measured by planimetry.

RESULTS

There was a significant increase in area and linear distance of India-ink inflow after pressure challenge in all groups (P < .05), but with important differences among them. When the sutured and unsutured groups from each CCI were compared, there was a significantly smaller area of inflow in the 2-step unsutured group (P < .05). The linear inflow was higher in both sutured groups; however, the difference was significant for the 2-step incision configuration only (P < .05).

CONCLUSIONS

A single radial suture reduced the area of inflow of bacterial-sized particles but increased the linear distance of inflow in single-plane 3.0 mm incisions. Suture placement in a stepped incision increased inflow of bacterial-sized particles.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: May William N, Castro-Combs Juan, Kashiwabuchi Renata T, Hertzog Hans, Tattiyakul Woranart, Kahn Yasin A, Hirai Flavio, Gower Emily W, Behrens Ashley. Bacterial-sized particle inflow through sutured clear corneal incisions in a laboratory human model.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2010.11.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.