OBJECTIVES

To determine the utility of spectral analysis in the differentiation of adductor-type spasmodic dysphonia (AdSD) from muscle tension dysphonia (MTD).

STUDY

DESIGN

Prospective blinded study.

METHODS

Forty-seven samples of AdSD-connected speech spectrograms from 27 subjects and 17 samples of MTD-connected speech spectrograms from 15 subjects were selected from clinical charts and de-identified. These spectrograms were reviewed independently and blindly by two speech language pathologists experienced in spectrography. The speech language pathologists designated the spectrogram as consistent with AdSD and MTD, and these designations were compared with actual clinical diagnoses.

RESULTS

The ability to differentiate AdSD from MTD with spectral analysis was 94% for rater #1 and 98% for rater #2. No MTD subjects were incorrectly diagnosed as having SD (100% specificity).

CONCLUSIONS

This study suggests that experienced speech language pathologists can distinguish AdSD from MTD with a high degree of sensitivity and specificity based on spectral analysis. Spectral analysis is especially useful in cases where perceptual analysis and clinical evaluation alone are insufficient.

Для цитирования: Rees Catherine J, Blalock P David, Kemp Shannon E, Halum Stacey L, Koufman Jamie A. Differentiation of adductor-type spasmodic dysphonia from muscle tension dysphonia by spectral analysis.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2007. DOI: 10.1016/j.otohns.2007.03.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.